coulomb-interaction <truncationType> [<args> ...]
Optionally truncate the coulomb interaction. The available <truncationType>'s and the corresponding arguments are:
Periodic
Standard periodic (untruncated) coulomb interaction (Default)
Slab <dir>=001|010|100
Truncate coulomb interaction along the specified lattice direction. The other two lattice directions must be orthogonal to this one. Useful for slab-like geometries.
Cylindrical <dir>=001|010|100 [<Rc>=0]
Truncate coulomb interaction on a cylinder of radius <Rc> bohrs with axis along specified lattice direction. The other two lattice directions must be orthogonal to this one. Rc=0 is understood to be the in-radius of the 2D Wigner-Seitz cell perpendicular to <dir>.
Wire <dir>=001|010|100
Truncate coulomb interaction on the 2D Wigner-Seitz cell in the plane perpendicular to <dir>. The other two lattice directions must be orthogonal to this one. Useful for wire-like geometries.
Isolated
Truncate coulomb interaction on the 3D Wigner-Seitz cell.
Spherical [<Rc>=0]
Truncate coulomb interaction on a sphere of radius <Rc> bohrs. Rc=0 is understood to be the in-radius of the Wigner-Seitz cell.
For all the truncated modes, the charge density must be confined to a maximum separation of L/2 in each truncated direction, where L is the length of the unit cell in that direction or 2 Rc for Spherical and Cylindrical modes. The center of the charge density is not important and may cross unit cell boundaries.
Requires: (None)
Forbids: (None)
Allow multiple: no
Default:
coulomb-interaction Periodic
Back to: Input file documentation or Index of commands